Touch Screen
Good Repeatability
The Parr 6100 Compensated Jacket Calorimeter continuously monitors the temperature surrounding the calorimeter and applies the necessary heat leak correction in real time. Despite the fact that it doesn’t have a temperature regulated water jacket found in traditional isoperibol calorimeters, the compensated jacket approach offers significant improvement over the traditional static jacket calorimeter. The application of the real-time jacket temperature to the heat leak correction avoids the long pre- and post- periods normally associated with static jacket calorimetry. In addition to achieving a rapid analysis, this technology allows the user to realize the precision required by the most frequently used standard test methods for commercial fuel testing.
As with all static jacket calorimeters, best results are obtained when the instrument is operated in a location where it is not subject to air drafts and fluctuating temperatures. The preferred operating environment is in a temperature controlled room (+/- 1 C). It is a well accepted principle of reliable analysis that any instrument calibration be checked regularly. The optimum frequency for checking the 6100 Calorimeter depends largely on the temperature stability of the operating environment. As general rule, the instrument calibration should be evaluated at least every tenth test. The colorimeter controller software conveniently offers both a graphical control chart approach in addition to an automatic rolling average calculation to support calibration maintenance and verification. Following the aforementioned guidelines and using reference samples, such as benzoic acid, the process sigma (precision classification) of the 6100 Calorimeter can be taken as 0.1%.
A Self-Contained Operating Unit
The 6100 Calorimeter is a compact operating unit that uses the same 1108 oxygen bomb and oval bucket furnished with the 6200 or with the 1266 and 1356 previous models. It also has the same automatic oxygen filling system and high precision electronic thermometer used in the 6200 Calorimeter. There is a touch-panel keyboard for data entry and a color LCD display for operator prompts, status indication, data verification and report views. All steps in the test procedure are managed by a microprocessor control system programmed to operate the calorimeter in either the conventional equilibrium mode or in a faster dynamic mode. All data is handled automatically by a dedicated microcomputer.
Printed Reports
An optional 1757 Printer can be furnished with each 6100 Calorimeter to produce a permanent record of all activity within the calorimeter.
Multiple Language Options
Parr Model 6100 can be set to provide the programming options, operating menus, reports and error messages in the following choice of languages: English, French, German, Spanish, Italian and Czech.
A 6100 Calorimeter consists of the following parts which are easily installed to provide a complete operating system. - Calorimeter module with built-in calorimeter controller.
- 1108 Oxygen Bomb
- Oval Bucket
- Accessories for installation
6100EA Calorimeter with 1108 Oxygen Bomb, 115V
6100EF Calorimeter with 1108 Oxygen Bomb, 230V
6100CLEA Calorimeter with 1108CL Oxygen Bomb for Chlorine Service, 115V
6100CLEF Calorimeter with 1108CL Oxygen Bomb for Chlorine Service, 230V
SUGGESTED OPTIONAL ACCESSORIES
1108 Oxygen Bomb, extra
1108CL Oxygen Combustion Bomb for Chlorine Service, extra
A391DD Oval Bucket, extra
1563 Water Handling System with measuring pipette without cooling.
6510 Water Handling System with measuring pipette and thermoelectric water cooler.
6109 Spare Parts Kit
2811 Pellet Press
Parr continues to offer the broadest range of oxygen bomb calorimetry available.
Please ask for a copy of our Calorimeter Catalog - 6000MB.
Model 6400 Calorimeter. For laboratories that require high through-put and minimum operator time between tests.
Model 6300 Calorimeter. For laboratories that require high through-put and minimum operator time between tests.
Model 6200 Calorimeter. For general laboratory testing or those that require special oxygen bombs or who prefer removable bombs.
Model 6100 Calorimeter. For laboratories that can accept a reduced level of precision.
Model 1341 Plain Jacket Calorimeter. For student instruction and occasional testing.