Series 4600 Pressure Vessel Systems, 1 & 2 L RFQ

Series 4600 Request for Quotation

An example order number for a vessel in this series is: 4600-1L-T-SS-VGR-2000

Click on the selections below to develop a composite identification number which may be used to request a quote for a 4600 Series Pressure Vessel.

Please note that all options and combinations are not compatible with all models.

AVessel Rating
-No Symbol Standard rating, 1900 psi at 350 °C (1 & 2 Liter Vessels)
-HP High pressure rating, 2900 psi at 350 °C (970 & 1900 mL Vessels)
BVessel Volume
-1000mL 1000 mL, 4″ ID (standard rating only)
-2000mL 2000 mL, 4″ ID (standard rating only)
-970mL 970 mL, 3.75″ ID (high pressure rating only)
-1900mL 1900 mL, 3.75″ ID (high pressure rating only)
CHead Mounting Style
-No Symbol Moveable Head (Standard configuration)
-FH Fixed Head
DGasket / Maximum Temperature
-T PTFE Flat Gasket, 350 °C
-OV FKM O-ring, 225 °C
-OK FFKM O-ring, 300 °C
-FG Flexible Graphite Flat Gasket, 350 °C
EMaterial of Construction
-SS T316 Stainless Steel
-C20 Alloy 20
-MO Alloy 400
-IN600 Alloy 600
-IN625 Alloy 625
-HB Alloy B-2/B-3
-HC Alloy C-276
-NI Nickel 200
-TI2 Titanium Grade 2
-TI4 Titanium Grade 4
-ZR702 Zirconium Grade 702
-ZR705 Zirconium Grade 705
See Materials of Construction for other available alloys.
FHead Configuration
-RD Rupture disc port with rupture disc assembly & disc
-1/8 One head opening, 1/8″ NPT port, plugged
-1/4 One head opening, 1/4″ NPT port, plugged
-B One head opening, “B” socket
-VGR Valve on gage adapter, pressure gage, rupture disc assembly, & thermocouple w/ thermowell
-NS Non-standard, custom head opening
GOptional Fittings & Custom Options (Check all needed)
-VD Single Valve on head with dip tube (VGR Required)
-DVD Double Valve Assembly on head with dip tube (VGR Required)
-SC Serpentine Cooling Coil
-BDV Bottom Drain Valve
-4310B Gage Block Assembly (for head with “B” socket opening)
-CAD Internal Catalyst Addition Device
-XCAD External Catalyst Addition Device
-SCP Solids Charging Port (Ball Valve)
-RC Reflux Condenser
-RTC Reflux/Take-Off Condenser
-WJ Welded Jacket
HPressure Gage (VGR and Gage Block only)
-No Symbol None
-3000 3000 psi / 207 bar
-2000 2000 psi / 138 bar
-1000 1000 psi / 69 bar
-600 600 psi / 40 bar
-200 200 psi / 14 bar
-100 100 psi / 7 bar
IStand and Heater Options
-No Symbol None
-BTH Bench top heater with base plate (moveable head only)
-BTS Bench top stand (moveable or fixed head)
-FC Floor cart (moveable head only)
-FS Floor stand (moveable or fixed head)
-FSP Floor stand with pneumatic lift (fixed head only)
JController
-No Symbol None
-4838 PID Control, Ramp & Soak Programming, and Data logging with Software. For use with one additional display module.
-4848 PID Control, Ramp & Soak Programming, and Data logging with Software (RS-485 to USB cable not included). For use with up to three additional display modules.
View a complete list of Controllers and options.
KController Options (Check all needed)
-PDM Pressure Display Module
-HTM High Temperature Cut Off Module
-ETLM External Temperature Limit Module
-SVM Solenoid Valve Module (for cooling control)
-A1925E4 RS-485 to USB Cable for 4838/4848 Controller (required for data logging)
-A1925E6 RS-485 to USB Converter, isolated, 30-ft
-A2208E RS-485 Daisy Chain for Multiple Controllers (Must be used with A1925E6)
-A3504HC SpecView Software Package for 4838/4848 Controller
LElectrical Supply for Heater and/or Controller
-No Symbol  None
-115 115V Heater
-230 230V Heater
MCertifications
-No Symbol No Certification
-ASME ASME Documentation
-CE CE Documentation
-P Parr Certification

Please note that all options and combinations are not compatible with all models.